Specifications At-a-Glance

 


Magna V
Clamp
Force
Injection
Size Range
Clamp
Stroke
Max.
Daylight
Min.
Mold
Max. Mold
Size
Rotary Table
Diameter
Shuttle
Stroke
Us Tons oz in in in in in in
30 30 0.73 - 6.04 7.5 14.0 6.5 8 x 12 39.0 19.25
50 50 0.73 - 6.04 13.0 19.0 6.0 10 x 16 48.0 23.03
80 80 2.27 - 11.9 14.5 22.0 7.5 12 x 18 54.7 26.45
130 130 3.51 - 28.0 15.0 25.0 10.0 16 x 20 58.0 33.5
200 200 3.51 - 28.0 15.0 25.0 10.0 16 x 20 58.0 33.5
280 280 11.0 - 34.0 23.5 35.0 11.5 24 x 32 77.0
Magna V
Clamp
Force
Injection
Size Range
Clamp
Stroke
Max.
Daylight
Min.
Mold
Max. Mold
Size
Rotary Table
Diameter
Shuttle
Stroke
kN g mm mm mm mm mm mm
30 27.2 20.7 - 171.4 190.5 355.6 165.0 203.2 x 203.2 991 489
50 45.5 20.7 - 171.4 330.2 482.6 152.4 254 x 406.4 1219 592
80 72.7 64.4 - 337.4 368.0 558.8 190.5 304.8 x 457.2 1390 926
130 117 99.5 - 794 381.0 635.0 254.0 406.4 x 508.0 1473 926
200 180 99.5 - 794 381.0 635.0 254.0 406.4 x 508.0 1473 851
280 254 311.0 - 1049 596.9 889.0 292.1 609.6 x 812.8 1956